{"id":3599,"date":"2026-08-06T12:48:08","date_gmt":"2026-08-06T12:48:08","guid":{"rendered":"https:\/\/www.e-rihs.pl\/?page_id=3599"},"modified":"2026-08-06T13:46:51","modified_gmt":"2026-08-06T13:46:51","slug":"fluorescencja-rentgenowska-artax-800","status":"publish","type":"page","link":"https:\/\/www.e-rihs.pl\/index.php\/fluorescencja-rentgenowska-artax-800\/","title":{"rendered":"Fluorescencja rentgenowska (Artax 800)"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>Dysponent<\/strong>: Muzeum Narodowe w Krakowie \u2013 LANBOZ<\/p>\n<p style=\"text-align: justify;\"><strong>Kontakt:<\/strong>\u00a0<a href=\"mailto:jdelhoyo@mnk.pl\">dr Julio del Hoyo Mel\u00e9ndez\u00a0<img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/fizyka.umk.pl\/~erihs\/wp-content\/uploads\/2016\/05\/koperta.gif\" alt=\"koperta\" width=\"14\" height=\"16\" \/><\/a><\/p>\n<p style=\"text-align: justify;\">Analiza sk\u0142adu pierwiastkowego metod\u0105 spektroskopii fluorescencji rentgenowskiej (XRF) jest wykonywana na spektrometrze fluorescencji rentgenowskiej Artax 800 (Bruker, Berlin, Niemcy). Umo\u017cliwia on wykonanie pomiaru punktowego, bez mo\u017cliwo\u015bci wykonywania map rozk\u0142adu pierwiastk\u00f3w.<\/p>\n<p style=\"text-align: justify;\">Spektrometr jest wyposa\u017cony w lamp\u0119 rodow\u0105 (Rh) oraz optyk\u0119 polikapilarn\u0105, umo\u017cliwiaj\u0105c\u0105 analiz\u0119 obszaru o \u015brednicy oko\u0142o 65 \u03bcm. Generator promieniowania rentgenowskiego pracuje przy napi\u0119ciu 50 kV i nat\u0119\u017ceniu pr\u0105du 300 \u03bcA, czas akwizycji dla ka\u017cdej analizy zwykle wynosi 45 s. Do precyzyjnego ustawienia wi\u0105zki na analizowanym obszarze wykorzystuje si\u0119 laser oraz kamer\u0119 zintegrowan\u0105 ze spektrometrem.<\/p>\n<div id=\"attachment_3616\" style=\"width: 1075px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-3616\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-3616\" src=\"https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2.jpg\" alt=\"\" width=\"1065\" height=\"497\" srcset=\"https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2.jpg 1065w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2-300x140.jpg 300w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2-1024x478.jpg 1024w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2-768x358.jpg 768w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF2-500x233.jpg 500w\" sizes=\"(max-width: 1065px) 100vw, 1065px\" \/><p id=\"caption-attachment-3616\" class=\"wp-caption-text\">Badanie XRF z wykorzystaniem instrumentu ARTAX &#8211; geometria pozioma<\/p><\/div>\n<p style=\"text-align: justify;\">Badany mo\u017ce by\u0107 ka\u017cdy obiekt, bez wcze\u015bniejszego przygotowania. Najcz\u0119\u015bciej badane s\u0105:<\/p>\n<ul>\n<li>obrazy (sk\u0142ad pigment\u00f3w),<\/li>\n<li>obiekty metalowe,<\/li>\n<\/ul>\n<p>sporadycznie:<\/p>\n<ul>\n<li>rze\u017aby,<\/li>\n<li>tkaniny.<\/li>\n<\/ul>\n<p>G\u0142owic\u0119 pomiarow\u0105 mo\u017cna ustawi\u0107 w geometrii pionowej lub poziomej.<\/p>\n<div id=\"attachment_3615\" style=\"width: 790px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-3615\" decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-3615\" src=\"https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF1.jpg\" alt=\"\" width=\"780\" height=\"520\" srcset=\"https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF1.jpg 780w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF1-300x200.jpg 300w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF1-768x512.jpg 768w, https:\/\/www.e-rihs.pl\/wp-content\/uploads\/2026\/08\/XRF1-450x300.jpg 450w\" sizes=\"(max-width: 780px) 100vw, 780px\" \/><p id=\"caption-attachment-3615\" class=\"wp-caption-text\">Badanie XRF z wykorzystaniem instrumentu ARTAX &#8211; geometria pionowa<\/p><\/div>\n<p style=\"text-align: justify;\">Dla ka\u017cdego obiektu wykonywane jest od kilku do kilkudziesi\u0119ciu pomiar\u00f3w w r\u00f3\u017cnych punktach w zale\u017cno\u015bci od pytania badawczego.<\/p>\n<p style=\"text-align: justify;\">Proces akwizycji i analizy widm XRF jest prowadzony z u\u017cyciem oprogramowania Spectra 5.3 (Bruker, Berlin, Niemcy). W raporcie umieszczamy wykresy przedstawiaj\u0105ce widmo z przypisanymi pierwiastkami oraz komentarz.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dysponent: Muzeum Narodowe w Krakowie \u2013 LANBOZ Kontakt:\u00a0dr Julio del Hoyo Mel\u00e9ndez\u00a0 Analiza sk\u0142adu pierwiastkowego metod\u0105 spektroskopii fluorescencji rentgenowskiej (XRF) jest wykonywana na spektrometrze fluorescencji rentgenowskiej Artax 800 (Bruker, Berlin, Niemcy). Umo\u017cliwia on wykonanie pomiaru punktowego, bez mo\u017cliwo\u015bci wykonywania map &hellip; <a href=\"https:\/\/www.e-rihs.pl\/index.php\/fluorescencja-rentgenowska-artax-800\/\">Czytaj dalej <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/pages\/3599"}],"collection":[{"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/comments?post=3599"}],"version-history":[{"count":6,"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/pages\/3599\/revisions"}],"predecessor-version":[{"id":3626,"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/pages\/3599\/revisions\/3626"}],"wp:attachment":[{"href":"https:\/\/www.e-rihs.pl\/index.php\/wp-json\/wp\/v2\/media?parent=3599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}